Example of Warm Autoantibody

How to Subscribe
MLS & MLT Comprehensive CE Package
Includes 183 CE courses, most popular
$109Add to cart
Pick Your Courses
Up to 8 CE hours
$55Add to cart
Individual course$25Add to cart
The page below is a sample from the LabCE course Antibody Detection and Identification. Access the complete course and earn ASCLS P.A.C.E.-approved continuing education credits by subscribing online.

Learn more about Antibody Detection and Identification (online CE course)
Example of Warm Autoantibody

In this example, the patient's plasma tests positive with both screening cells at a strength of 2+.
Rh-HrKellDuffyKiddLewisMNSsLutheran
VialDonorDCcEefVCwKkKpaKpbJsaJsbFyaFybJkaJkbLeaLebMNSsLuaLubISAHGCC
IR1R1++00+000++0+0++++00++00+0+02+NT
IIR2R2+0++00000+0+0++0+++0++++0+02+NT
The screening cells, autocontrol, and all panel cells show reactivity at the AHG phase, which indicates a possible warm autoantibody.
Rh-HrKellDuffyKiddLewisMNSsPLutheran
Donor Cell NumberDCcEeCwKkKpaKpbJsaJsbFyaFybJkaJkbLeaLebMNSsP1LuaLubISAHGCC
1++00+00+0+0++0+++0+++++0+02+NT
2++00++++0+0+++0+0+0++++0+02+2+
3+0++000+0+0+0+0+0++00++0+02+2+
4+0+0+00+0+0+00+00++++0+0+03+NT
50++0+00+0+0++++++00+0+00+02+NT
600+++0++0+0+0+++0+++++00+02+NT
700+0+00+0+0++00++0+00++0+02+NT
800+0+00+0+0+++0+0+++++00+02+NT
900+0+00+0+0++++00+0++0+0+02+NT
10+0+0+0++0+0+0+0+0+0++0+0+02+NT
AC02+NT